1. Disconnect the unit from the power source.
2. Remove the three screws on the faceplate.
3. Carefully pull the faceplate away from the unit until the white Molex connector is exposed.
4. Disconnect the Molex connector.
5. Locate the bypass plug included in the accessory kit.
6. Plug the bypass plug into the male Molex connector.
7. Connect power to the unit (the unit should turn on immediately). If any of the components are not operational,
disconnect power immediately and contact Customer Service. If all components seem to be operating correctly,
allow the unit to run for 4 hours. Monitor the temperature of the cellar to determine if the unit is cooling properly.
8. Once the test is complete, remove the bypass plug. Plug the Molex connector back in to the controls wiring harness.
9. Replace the control and faceplate.
BYPASS TEST PROCEDURE