ACTIVE HUMIDITY OPTION OVERVIEW
Use of the Active Humidity Option
Humidity may uctuate in the wine cellar. The Active Humidity Option stabilizes the environment by adding moisture when the
wine cellar is becoming dry. Using a humidistat and a water source, the Active Humidity Option is able to regulate and establish a
humid environment suitable for wine storage.
Note: The ideal humidity of a wine cellar is between 50-70%.
Accessory Included with Active Humidity Option:
(1) 25 ft. Humidistat Cable
(1) Dayton Humidistat
General Active Humidity Option Recommendations
Water source needs to have at least 40 psi.
Water tubbing size: 1/4” O.D
Water source should be tested for content and characteristics.
In areas that are known to have hard water, the use of a Water-Softener System is required.
Note: Failure to install a Water-Softener or a Filtration system will allow an
excessive particle residue buildup and may lead to system failure.
Even if the area is not known to have hard water, the use of a Filtration System (Particle Filter) is required.
Clean the evaporator coil every 3 months to remove particle residue buildup.
It might be best to use a Self-Piercing Saddle Valve as a simple connection to a water source.
Clean or replace the Misting Nozzle every 12 months.
Water Flow Order
The water supply should pass through either
a Water-Softener or a Filtration system before
reaching the unit as shown in Figure 2.
Route a 1/4” Copper, Pex or equivalent tubing from
the water source and connect to the water inlet
tting on the unit as shown in Figure 3.
Turn on the water and check for leaks.
Self-Piercing Saddle Valve
Install a Self-Piercing Saddle Valve to a near by water supply for
simple connection to a water source as shown in Figure 1.
Do not allow water leakage inside of the Unit.
TUBING OUTLET
OPTIONAL INSERT FOR
PLASTIC TUBING
WATER SUPPLY
Figure 2
Figure 3
Figure 1
FILTRATION SYSTEM
COOLING UNIT
MISTING NOZZLE
ACTIVE HUMIDITY SPECIFICATIONS
Power Consumption 0.2 amps @ 120V/60 Hz
dBA TBD
Humidistat Range 30-90% RH
Humidistat Accuracy ± 1%
Humidistat Adjustment
Increments
1%
Water Supply Feed Rate 0.63 gph @ 40 psi