CONTROLLER FUNCTIONS
If your unit has a remote keypad then you will have the Remote Controller.
Button Normal Functions
ON/OFF The ON/OFF button allows the customer the convenience of turning the refrigeration
system ON or OFF, from the control panel. This feature does not disconnect power from
the unit. In order for the power to be shut o from the unit, the power cord must be
unplugged from the wall receptacle.
Press the ON/OFF button once for button application.
Up and Down
Arrows
Use these buttons to scroll up or down the CPSM (Customer Preference Selection Mode)
menu.
Displays the Highest and Lowest temperature sensed by the Bottle Probe. This feature
allows the customer instant access to the recorded data applicable to the Bottle Probe
Temperatures, it can be easily reset to reect current temperatures.
1. Press the “UP arrow, or the “Down” arrow once, and the Highest or Lowest Temperature
(Hi/Lo) sensed by the Bottle Probe, will be displayed.
2. To reset the Hi/Lo, press and hold the “Set button when the Hi/Lo value is displayed on
the Digital Display. Continue to hold the “Set button until rst appears on the digital
display and then blinks. This will erase the past recorded Temperature Data History and
start recording, from the current time and temperature, forward. Temperatures displayed
would reect Bottle Probe Temperatures from that point in time, and beyond.
3. The Hi/Lo feature should be reset at initial “Start-Up and after the Cellar or Cabinet has
obtained normal operating temperatures, which is generally 55°F.
Cellar PreChill (CPC) The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC logo
will be displayed on the digital display. The CPC feature can be terminated by pressing the
Up button for 3-5 seconds, or the feature will self terminate after 6 hrs.
1. The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm
Product. The feature will shift the Set Point down to a lower setting of 52°F, for the next 6
hours. After the 6 hour time period, the Set Point will automatically return to the original
Set Point.
2. The CPC feature can be conveniently adjusted to the customer’s specic needs, by
accessing the “Customer Preference Select Mode” (CPSM). See Customer Preference
Select Mode Instructions.
Display
Set Point
ON / OFF
Low Temp
High Temp / Pre-Chill
TEMPERATURE